2.2KW VFD Spindle Inverter 110VAC Input With 2.2KW Water Cooled Spindle,110VAC

$425.00
In stock
In stock
SKU
2.2KWSWC
 

2.2KW VFD Spindle Inverter 110VAC Input With 2.2KW Water Cooled Spindle,110VAC

This kit includes:

1:

2.2KW (3HP) VFD FOR SPINDLE (KL-VFD22-110V) 110VAC INPUT

Input: 110VAC ±20%  1 or 3 Phase (R,S or R, T or S,T)    50/60Hz

Output: 110VAC 3 Phase (U,V,W)   2.2KW

(U,V,W) Frequency Range: 0.5-400Hz

0-10V Analog interface capability

Variable speed

2:

KL-2200 2.2KW Spindle 110V 

OD=80 mm

Length =215 mm

Voltage: 110V

Speed: 8000-24000 R/min ( run speed at 60% or less than 80% of rated Max spindle)

Power: 2200 W (3HP)

Frequency: 400 Hz

Water Cooling,

ER20 Collet chuck. (But tool is not included: you can use 1/16", 3/32", 1/8", 3/16", 7/32", 1/4", 5/16", 11/32", 3/8", 13/32", 7/16", 1/2" )

Grease Lubrication,

Runout off: less than 0.005mm

Water cooling about 20-26 gal/hr

about 15 ibs

VFD Parameter Set:

PD000=0 for Parameter unlock ( 1 ) for Parameter Lock

PD001=0 (1 For Remote Control)

PD002=0 ( 1 For 0-10v Terminal Control or Remote Trim Pot Control )

( J1 Also Needs to be set for Terminal Control)

PD003=400

PD004=400

PD005=400

PD007=20

PD008=110 (Motor Rated Voltage, If you have 220v spindle then set to 220v )

PD009=15

PD010=8

PD011=120 ( 100 Minimum Setting with Quality VFD, 120 is Safe)

PD13= 08 is for Factory reset, Only use this to set VFD to Factory Default SettingsPD014

Acceleration = 12 ( Adjust to suit)

PD015 Deceleration=12 (Adjust to suit) ( PD15 is ignored IF PD26=1 Then the Spindle will

Coast to a Stop)

PD141=110 ( Motor Rated Voltage ) (220 for VFD Rated for 220v )

PD142= ( Motor Max Amps)

PD142=( 220v Set for your motor Amp Rating 2.2Kw Spindle

9 amp )

PD142=( 220V Set for your motor Amp Rating 1.5Kw Spindle 7 amp )

PD142=( 220v Set for your motor Amps Rating 800w Spindle 4 amps )

PD142=( 120v Set for your motor Amp Rating 800w Spindle 7 amp )

PD143=2 ( Motor Number of Poles)

PD144=3000 (Max Motor RPM) =3,000= (24,000)

PD70=0 ( This may need to be set to 1 if Control Voltage is 0-5v )

PD72=400

PD73=120 ( 100 Minimum Setting )

If you have E. Lv. S error code alarm

Pls set

PD200=65535

PD209=70

Manuals & Downloads

Thanks to our customer.

click here for video by cuttingtooldesigner

One year manufacture warranty