Before starting the configuration and file installation, we recommend creating a backup of the current installation by right-clicking in the current installation folder and zipping it.
Press the knob three times to enter test mode in the THC and observe the ARC OK signal activate.
Turn the knob up or down to move the axis and observe the Torch UP and Torch Down LEDs activate when moving in each direction. The Z-Axis should also move to adjust the position.
To exit test mode, press the knob once.
This instruction has been updated for these instructions.