Plasma Touch Sensor Configuration for UCCNC
Software version: 1.2114
Before starting the configuration and file installation, we recommend creating a backup of the current installation by right-clicking in the current installation folder and zipping it.
STEP 1: Probe pin configuration. This is the pin used to sense the probing action. This pin will go high when the probe touches the plate.
STEP 2: Probe Enable Configuration. This is the pin assigned to enable the probe. This pin will go high while probing.
STEP 3: To test the PTS-1, you can use this code, which does not require a special macro. Note that you could modify your post to generate the required probing commands.
SAMPLE PROBING GCODE:
N0050 F20 (Set the Probing Speed 20mm/sec)
N0060 G31 Z-10 (Start probing action on the Z-axis to a depth of up to 10mm)
N0070 G91 Z2 (After probing, move the Z-Axis 2mm up. This sets the motion to relative mode)
N0080 G90 (Set motion mode back to absolute)
N0090 M03 (Start the Torch)
N0100 G04 P2000 (Set a Pause of 2 seconds to allow the pierce time.)
N0110 G01 X5 (Cutting a 5mm square.)
N0120 Y5
N0130 X0
N0140 Y0
N0150 M05 (Turn off the Plasma)