📄 C92–MODBUS SERVER




   C92 – MODBUS SERVER

 

 

 

                                                                                            MAY  2024


 


 

1.0         OVERVIEW

This card provides you with a serious Modbus or TCP / IP connection and has 3 configurable ports for TTL outputs and an analog port

 

2.0         FEATURES

 

  • ·MODBUS TCP/IP and USB protocol.
  •  Pins 2-9 on IDC26 can be bi-directional, determined by the internal configuration.
  • Presentation Screen LCD        
  •  It can be powered with a voltage of +5V, via the IDC26 pin, or from the USB connector.
  • Compatible with the CNC controller board.
  •  3 Expansion Ports.  It has 3 x IDC26 connectors for additional Breakout or Relay Boards.
  •  IDC 8-pin male for analog input
  •  Visualization of the state of the pins on the display with TCP / IP
  •  IP configurable
  •  A display and an encoder for configuration
  •  Din rail mountable.

 


3.0         DESCRIPTION

 

4.0         TERMINAL POWER

Regulated 5VDC @0.5A is required to power this board

                                                                 

⚠️

WARNING:  Check the polarity and voltage of the external power source and connect the 5VDC and GND. Overvoltage or reverse-polarity power applied to these terminals can cause damage to the board, and/or the power source.

 

5.0         MODBUS COMMUNICATION PROTOCOL

 

5.1      USB Communications

For Modbus RTU (Remote Terminal Unit) mode communications, the default parameters are the following:

Baud Rate = 38,400bps
Data Bits = 8
Parity = None
Stop Bits = 1
Flow Control = None

               

 

5.2      Configuring the control software

 To configure, use the following sample configuration screen:

 

 

 

5.3      TCP/IP Communications

 For Modbus TCP mode communications, the default parameters are the following:

IP address = Configurable in Board C92
Port number = 502

 

5.4      Configuring the control software

 To configure, use the following sample configuration screen:

 

 

 

5.5      Board Modbus addresses

 Analog, Input and output pin discrete. 

 

FUNCTION NAME

FUNCTION TYPE

DISCRETE OUTPUT

Write SingleCoils

ANALOG INPUT

Read InputRegisters

DISCRETE INPUT

Read Inputs

 

 

6.0         PINOUT

6.1      PORT_1

 

                                      

IDC26 PIN

ADDRESS MODBUS

 

1

100 OUT

2

104 IN/OUT

3

105 IN/OUT

4

106 IN/OUT

5

107 IN/OUT

6

108 IN/OUT

7

109 IN/OUT

8

110 IN/OUT

9

111 IN/OUT

10

112 IN

11

113 IN

12

114 IN

13

115 IN

14

101 OUT

15

116 IN

16

102 OUT

17

103 OUT

18 - 25

GND

26

+5VDC

 

  

6.2      PORT_2

                                    

IDC26 Pin number

ADDRESS MODBUS

 

1

200 OUT

2

204 IN/OUT

3

205 IN/OUT

4

206 IN/OUT

5

207 IN/OUT

6

208 IN/OUT

7

209 IN/OUT

8

210 IN/OUT

9

211 IN/OUT

10

212 IN

11

213 IN

12

214 IN

13

215 IN

14

201 OUT

15

216 IN

16

202 OUT

17

203 OUT

18 - 25

GND

26

+5VDC

 


6.3      PORT_3

 

                           

IDC26 PIN

ADDRESS MODBUS

 

1

300 OUT

2

304 IN/OUT

3

305 IN/OUT

4

306 IN/OUT

5

307 IN/OUT

6

308 IN/OUT

7

309 IN/OUT

8

310 IN/OUT

9

311 IN/OUT

10

312 IN

11

313 IN

12

314 IN

13

315 IN

14

301 OUT

15

316 IN

16

302 OUT

17

303 OUT

18 - 25

GND

26

+5VDC

 

6.4      PORT ANALOG INPUT

0-5vdc analog signals with 10bit ADC.

                                                             

IDC8 PIN

ADDRESS MODBUS

 

1

400

2

401

3

402

4

403

5

404

6

405

7

406

8

407

  

7.0         CONFIGURE MENU

 

Press the knob for 2 seconds to enter setup mode.

Navigate through the setup menu by turning the knob.

Press the knob to change settings.

Turn the knob to adjust the value.


8.0         DIMENSION

 

                         

All dimensions are in millimeters

Fixing a hole (3mm).


💡

DISCLAIMER

Use caution. CNC machines can be dangerous. Neither IGNITE, LLC nor Arturo Duncan is liable for any accidents resulting from the improper use of these devices.  This product is not a fail-safe device, and it should not be used in life support systems or in other devices where its failure or possible erratic operation could cause property damage, bodily injury, or loss of life.